{"product_id":"sevcon-gen4-hvlp-20-liquid-cooled-inverter-700v-20kw","title":"Sevcon HVLP-20 Auxiliary Inverter - 700V 22kW","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003eHigh-Power Precision for Liquid-Cooled Auxiliary Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"6\"\u003eSevcon HVLP-20\u003c\/b\u003e is the high-capacity variant of the HVLP series, designed for demanding auxiliary loads in 800V electric vehicle architectures. Delivering up to \u003cb data-index-in-node=\"166\" data-path-to-node=\"6\"\u003e22kW of continuous power\u003c\/b\u003e, this liquid-cooled inverter is the industry standard for driving heavy-duty air conditioning compressors, large hydraulic pumps, and thermal management systems in electric buses, trucks, and specialized industrial machinery.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eTechnical Specifications (Verified Data):\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003e634L20101 \/ 634L20202 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003e\u003cb data-path-to-node=\"8,2,0,0\" data-index-in-node=\"0\"\u003eOperating Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003e150V DC to 800V DC (Nominal: 700V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003e\u003cb data-path-to-node=\"8,3,0,0\" data-index-in-node=\"0\"\u003eContinuous Output Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e\u003cb data-path-to-node=\"8,3,1,0\" data-index-in-node=\"0\"\u003eUp to 22kW @ 700V DC\u003c\/b\u003e (Liquid Cooled)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003e\u003cb data-path-to-node=\"8,4,0,0\" data-index-in-node=\"0\"\u003ePeak Output Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e\u003cb data-path-to-node=\"8,4,1,0\" data-index-in-node=\"0\"\u003e53A (Arms)\u003c\/b\u003e for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003e\u003cb data-path-to-node=\"8,5,0,0\" data-index-in-node=\"0\"\u003eContinuous Output Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e33A (Arms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003e\u003cb data-path-to-node=\"8,6,0,0\" data-index-in-node=\"0\"\u003eLogic Supply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e12V or 24V nominal (8V - 36V range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003e\u003cb data-path-to-node=\"8,7,0,0\" data-index-in-node=\"0\"\u003eEnvironmental Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e\u003cb data-path-to-node=\"8,7,1,0\" data-index-in-node=\"0\"\u003eIP66 Rated\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003e\u003cb data-path-to-node=\"8,8,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e5.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"9\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e🛡️ Safety \u0026amp; Integration Note\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eHigh Voltage Safety:\u003c\/b\u003e Operates at lethal voltages (up to 800V DC). Integrated \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"77\"\u003eHVIL (High Voltage Interlock Loop)\u003c\/b\u003e circuitry is standard to ensure system-wide safety during maintenance and operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eControl Intelligence:\u003c\/b\u003e Features advanced Flux Vector Control for precise management of both AC Induction and Permanent Magnet (PMAC) motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eProgramming:\u003c\/b\u003e Full parameter access and diagnostics require an \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"62\"\u003eIXXAT USB-to-CAN\u003c\/b\u003e interface and \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"93\"\u003eDVT\u003c\/b\u003e software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e💧 Critical Cooling \u0026amp; Performance Note\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eLiquid Cooling Requirement:\u003c\/b\u003e To achieve its 22kW rating, the HVLP-20 requires an active liquid cooling circuit (typically a 50\/50 water-glycol mix). Ensure a minimum flow rate of 6 L\/min for optimal thermal performance and to prevent power derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eSuperior Power Density:\u003c\/b\u003e Compared to the HVLP-10, the HVLP-20 doubles the power output within a similarly rugged footprint, making it ideal for high-duty cycle industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e🌟 Sourcing from Ekol Drive Systems\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eAuthorized Partner:\u003c\/b\u003e Genuine Sevcon liquid-cooled technology supplied via Ekol Engineering’s official distribution network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eGlobal Export Authority:\u003c\/b\u003e Approved by \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"37\"\u003eUK Strategic Export Controls\u003c\/b\u003e for international trade, ensuring all EUSU\/SU documentation is handled with 100% legal compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eEXW (Ex Works) Terms:\u003c\/b\u003e All sales are conducted on EXW terms from our UK facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e\u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"0\"\u003eSeamless Customs Support:\u003c\/b\u003e Commercial invoices include official export license declarations for fast and reliable global customs clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Turntide","offers":[{"title":"Default Title","offer_id":54675065504035,"sku":null,"price":2090.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0970\/7074\/3843\/files\/turntide-hvlp-20-high-voltage-auxiliary-inverter-700v-53a-liquid-cooled-sevcon-replacement-ekol-engineering.png?v=1770059168","url":"https:\/\/products.ekolltd.com\/products\/sevcon-gen4-hvlp-20-liquid-cooled-inverter-700v-20kw","provider":"Ekol Engineering","version":"1.0","type":"link"}